Multielectrode Array (MEA)

 ✓ Measure electrical signals at multiple locations throughout the culture

✓ Mimic biophysical in vivo microenvironment

✓ Lowest cost MEA electrophysiology data acquisition system

One of the substantial weaknesses of in vitro experiments is their failure to replicate the conditions of cells in an organism. Isolated and cultivated primary cells on rigid MultiElectrode Arrays (MEAs) differ significantly from the corresponding cell type in vivo, limiting the predictive value of in vitro data. BMSEED’s stretchable MultiElectrode Arrays (sMEAs), which contains elastically stretchable electrodes embedded in an elastomeric matrix that contact the cell or tissue culture, address this challenge by reproducing the mechanical and electrical environment of cells in vivo in a controlled environment in vitro. sMEAs enable mechanical stretching, optical imaging, and electrical stimulation/recording, bridging the gap between in vitro and in vivo research to enhance the relevance of experimental data.


Why Our MultiElectrode Arrays?

Reduced cost and complexity compared to other electrophysiological techniques

Real-time, in-situ, and label-free measurements

✓ Suitable for dissociated cell cultures, slices, and organoids

✓ Record from up to 120 microelectrodes simultaneously

Chronic and acute experiments

✓ Mimic biophysical in vivo microenvironment to more accurately predict in vivo behavior using in vitro data

Electrically stimulate cells in culture

Largest variety of multielectrode arrays (2D, 3D, soft, traditional)

✓ Assess efficacy and toxicity of drugs

How can we help?
Our team of experts...

Oliver Graudejus
Founder
Phone: +1 (609) 532-9744
Email: oliver@bmseed.com

Application Fields of MultiElectrode Arrays

(I) Better Predict in vivo Behavior with in vitro Data

  • Biomimetic soft substrates (as opposed to glass or plastic)

  • Mimic bio-mechanical and bio-electrical microenvironment of cells in vivo

  • Use hiPSC-derived human cells

  • Tight control of experimental parameters for repeatable and reproducible experiments

BMSEED’s stretchable multielectrode arrays (sMEAs) are the ONLY MEAs that allow the application of mechanical cues in conjunction with electrophysiological measurements.

(II) Neurotrauma Research: Traumatic Brain Injury (TBI) & Spinal Cord Injury (SCI)

  • Mimic stretch and compression injury in vitro using dissociated cell or tissue slice cultures

  • Directly assess the impact of the injury on cellular health and function using non-invasive electrophysiology measurements

  • Directly compare post-injury electrophysiology with pre-injury data

  • Apply multiple injuries, e.g., to mimic repeated concussions

  • Apply different strain profiles (radial, uni-axial, other) to mimic different types of injury using the same equipment

  • Highly reproducible parameters for repeatable experiments

  • Assess neuroprotective properties of drugs to mitigate the damage after the injury

BMSEED’s stretchable multielectrode arrays (sMEAs) are the ONLY MEAs that are compatible with stretch injury models.

(III) Cardiac Research

  • Improve maturity of cardiac cells to exhibit an adult-like phenotype by applying  bio-mechanical cues to the culture

  • In vitro results for efficacy and toxicity of drugs are more predictive of in vivo behavior (reduced failure rate for clinical trials)

  • Monitor cardiac differentiation and maturation in vitro using label-free electrophysiology measurements

  • Use electrical stimulation for controlled pacing of cardiomyocytes

  • Evaluate cardiotoxicity and proarrhythmic effects of drug candidates

BMSEED’s stretchable multielectrode arrays (sMEAs) are the ONLY technology that combines mechanical and electrical stimulation of cell cultures with electrophysiological measurements.

(IV) Other Application Fields of MultiElectrode Arrays

  • Mechanobiology

  • Bottom-up neuroscience

  • Pain research

  • other

Ask us whether your research would benefit from using multielectrode arrays.


What Clients Say About our MultiElectrode Arrays

Tuneable parameters and very fast to use.”

-A. Pybus, Ph.D. Georgia Institute of Technology

Easiness for acquiring electrical signal in a non-invasive manner.”

-A. Patino, Ph.D. Arizona State University

“The most valuable thing is that we can record from cells multiple times…injure and record on the same device.”

-M.K. Dwyer, M.S. Columbia University


a) organotypic hippocampal slice cultures (OHSCs), long-term potentiation (LTD) & long-term depression (LTD) induced post-injury; b) primary hippocampal neurons (PHNs) & brain tissue tolerance to traumatic brain injury (TBI); c) organotypic spinal cord slice cultures (OSCSCs) & cypin regulated pain sensitivity after spinal cord injury (SCI); d) human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), hiPSC-CM differentiation; e) neurons, astrocytes, & microglia, pro-inflammatory signaling & immune response to mild traumatic brain injury (mTBI)

How can we help?
Our team of experts...

Oliver Graudejus
Founder
Phone: +1 (609) 532-9744
Email: oliver@bmseed.com

MultiElectrode Array Systems

BMSEED’s MEA Electrophysiology Data Acquisition System is available as a stand-alone equipment or integrated with a cell stretcher and imaging capabilities (MEASSuRE platform)

Stand-Alone

  • 120 channel electrophysiology controller

  • 60 or 120 channel recording and stimulation of electrophysiological activity

  • Stimulation currents from 10 nA - 2.55 mA

  • Analog and digital stimulation triggers

  • Compatible with stretchable microelectrode arrays (sMEAs) and glass microelectrode arrays (gMEAs)

  • Low-cost, high performance data acquisition system for electrophysiology

Contact us for pricing information.

Integrated in MEASSuRE Platform

  • Mechanics Module: stretching at strain rates up to 90/s and strains up to 50%

  • Imaging Module: optical or fluorescence imaging during stretching

  • Electrophysiology Module: 2x60 channels for recording and stimulation

Contact us for pricing information.


Glass MEA

Hard & rigid

60/120 channels

Recording

Stimulation

2D (flat)

2D cultures, slices

3D-Glass MEA

Hard & rigid

60/120 channels

Recording

Stimulation

3D (small spikes)

Organoids, slices

Microfluidic MEA

Soft & stretchable

30 channels

Recording

Stimulation

3D (microfluidic)

3D cultures

Stretchable MEA

Soft & stretchable

30/60 channels

Recording

Stimulation

2D (flat)

2D cultures, slices

Pocket MEA

Soft

30/60 channels

Recording

Stimulation

3D (pocket)

Organoids


Frequently Asked Questions About our MultiElectrode Arrays

1. What is a multi-electrode array?

Tools for Electrophysiological Recording and Stimulation

Multielectrode arrays (MEAs), also known as microelectrode arrays, are microfabricated platforms designed for electrophysiological investigations. They consist of a dense grid of small electrodes fabricated from biocompatible and electrically conductive materials, such as gold, platinum, or titanium. These electrodes are typically deposited onto a substrate material offering varying degrees of rigidity (glass), flexibility (polyimide), or stretchability (PDMS).

MEAs offer a versatile tool for studying excitable tissues both in vitro (cultured cells) and in vivo (living organisms). Their primary function involves:

  • Electrophysiological recording: By virtue of their close proximity to living cells, MEAs passively capture the minute voltage fluctuations associated with cellular activity (e.g., action potentials, synaptic events) in the extracellular space.

  • Electrical stimulation: MEAs can also be employed to deliver controlled electrical currents to stimulate cells, enabling researchers to probe cellular responses or modulate network activity.

The broad applicability of MEAs, including both traditional rigid and novel stretchable configurations offered by BMSEED, allows researchers to investigate diverse biological phenomena, ranging from cellular electrophysiology and network dynamics to drug discovery applications.

2. How does a multi-electrode array work?

Multielectrode arrays are critical components in the process of acquiring electrical signals from cells. We describe briefly the process of how MEAs are used in recording and stimulation of electrophysiological activity.

  1. Cellular Interface: The MEA surface is typically composed of biocompatible materials and presents a microfabricated grid of microelectrodes (e.g., gold, platinum) for intimate contact with cultured cells. This biocompatibility enables acute and long-term (months) electrophysiological studies.

  2. Extracellular Recording: As excitable cells (neurons, cardiomyocytes) adhere and form networks on the MEA, their electrical activity (action potentials, synaptic events) generates minute voltage fluctuations (typically 10s to 100s of μV) in the extracellular space.

  3. Signal Transduction: These voltage changes are passively captured by the electrodes due to their close proximity to the cells. The microelectrodes on the MEA basically transduce ionic currents in the medium that are caused by cellular electrical activity into electronic currents.

  4. Signal Processing: The acquired signals are weak and require amplification to enhance their amplitude for further analysis. The amplifiers on the headstage amplify the differential signal of recording and reference electrodes. The amplifiers on BMSEED’s MEA electrophysiology system are placed in proximity to the electrodes to minimize noise.

  5. Noise Elimination: Filtering techniques are employed to eliminate unwanted electrical noise originating from the environment or the MEA itself. BMSEEED’s MEA electrophysiology system has a notch filter to eliminate 50Hz and 60Hz line noise, as well as low-pass filters and high-pass filters with adjustable frequencies.

  6. Data Acquisition: The amplified and filtered signals are then digitized and transferred to a computer system for further processing and analysis.

  7. Electrophysiological Analysis: Specialized software allows researchers to analyze the recorded activity, including spike sorting (identifying individual neuron activity), network analysis (evaluating communication patterns), and field potential characterization (understanding overall network behavior). Ask BMSEED for the NeuroExplorer software.

MEAs offer a minimally invasive approach for studying large ensembles of excitable cells, providing valuable insights into cellular electrophysiology, network dynamics, and drug discovery applications.